CD425-D (220V)

HVAC

Voltage Requirements :
220/1/60
Effective Volume :
1,500m3
Typical Extraction :
285 ppd
CD425-D (220V)

• Digital Humidity Control
• Welded steel chassis with baked epoxy-coated and vinyl coatings for abrasion and corrosion resistance
• An adjustable humidistat to control the level of dryness desired
• System lamps to report the operating status of the unit
• EIPL’s unique “Reverse Cycle” defrosting system, for effective operation in low ambient temperatures down to 33°F
• Ductability
• Rugged design for harsh industrial environments

Options

• Available in 460V Power Supply (8 Amp)
• Internal High Capacity Condensate Pump
• Low Temperature Operation, Down to 0°F

CD425-D - 220V CD425-D - 220V with Pump
Part Number 10146BR-US 10147BR-US
Height (inch) 47 47
Width (inch) 43 43
Depth (inch) 19 19
Weight(lbs) 353 353
Voltage 220 220
Phase 3 3
Frequency(Hz) 60 60
Power(W) 3680 3680
Current(A) 16 16
Airflow(m3/hr) 2,975 2,975
Noise Level(dba) 69 69
Refrigerant R407c R407c
Effective Volume(m3) 1,500 1,500
Typical Extraction 285 285
Min Operating Temp (°F) 33 33
Max OperatingTemp (°F) 95 95
CD425-D
Part Number 10146BR-US 10147BR-US
On/Off Control Y Y
Electronic Defrost Control Y Y
Compressor Restart Delay Timer Y Y
Compressor Type Reciprocating Reciprocating
Free Standing Y Y
Adjustable Control Humidistat Y Y
Reverse Cycle Defrost System Y Y
Status Indicators Y Y
High Capacity Water Pump N Y
Power On Indicator Y Y
Epoxy Powder Coating Y Y
Gravity Drain (2 X 5/8” O/D) Y N
CD425-D  (220V)

1x CD425-D - 220V Dehumidifier
1x CD425-D - 220V Owner’s Manual
1x 3/8" PVC Tube I/D – 7.8M long

CD425-D  (220V) with Pump

1x CD425-D - 220V Dehumidifier
1x CD425-D - 220V Owner’s Manual
1x 3/8" PVC Tube I/D – 7.8M long

How a Dehumidifier Works

1. Air is drawn into the  unit by a fan
2. Air passes over a cold surface
3. As the air is cooled, it’s moisture condenses
4. Water falls into the container
5. Air is re-heated by the heat recovery system
6. Air passes back into room 2°C warmer and considerably dryer
7. Defrost system automatically  de-ices unit as necessary
8. Unit switches off automatically when container is full
9. When the unit achieves the selected level of dryness it switches off automatically

Application

The EIPL CD425-D range of units were developed to serve the demands of industry for environmental control of very large areas in addition to areas affected by severe conditions. Warehouses, factories, offices and other large scale facilities with ambient temperatures ranging from 33°F to 95°F can be cured of humidity and condensation problems efficiently and automatically without over burdening costly heating, cooling and ventilation systems.The CD425-D units can be utilized singly or in multiple units to provide protection on any scale. Ducted applications are possible where design requirements specify.

Proven Performance

The EIPL CD425-D range of dehumidifiers are“stand alone” units that can handle the extra load encountered in the typical humid, industrial settings. Under maximum conditions, the CD425-D will condense and remove up to 50 gallons of water vapor per day – day after day. With “ReverseCycle” defrosting, this workhorse can function smoothly in a cold, wet location, without the limitations of frost buildup.

The Problem

Excess humidity in your crawl space, warehouse, office, factory or shop results in corrosion, mold growth and rotting. Enormous costs are incurred every year through damage to inventory and through inflated building maintenance costs as a result of dampness.Even if your building seems dry during the day, at night when the temperature falls the humidity rises and the condensation process begins. The compact physical size, and high performance, makes the CD425-D the ideal choice

The Dehumidifier

EIPL dehumidifiers are effective solutions to environmental control problems. The CD425-D range ofunits are high capacity dehumidifiers, made to operate at high efficiencies by removing moisture from the air through the refrigeration process. The fan draws the moist air through the cold evaporator coil, which cools the air below its dew point. Moisture forms on the evaporator coil and is collected in the condensate tray, which is equipped with an internal condensate pump for easy removal of collected moisture. The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase, plus the additional heat generated by the compressor. The air is, therefore, discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered. Continuous circulation of air through the dehumidifier gradually reduces the relative humidity within the area. The CD425-D allows a specific humidity level to be entered and also provides an actual display of the room humidity level. The CD425-D range of units will self regulate the drying required, and automatically switch on and off to save energy and expense by maintaining the desired level of humidity with intermittent operation.

Request a quote…

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.